Icynene®, the leading soft foam insulation and air barrier material, is becoming the industry standard for providing maximum building envelope performance. Icynene's pour and spray formulations represent a breakthrough in the science of moisture and thermal management.

Icynene® is the leading 100% water-blown foam insulation that minimizes air leakage for increased energy efficiency, creates a healthier indoor environment, reduces airborne sounds and offers greater design freedom. Icynene® maintains its performance with no loss of R-value over time. It does not shrink, sag or settle. Icynene® adheres to most construction materials and is the perfect insulation for walls, attics, ceilings and floors.
Ryan Haydel, Icynene Specialist
 
 
Key Icynene Applications

Icynene® is ideal for insulating and air-sealing both wood and steel framing.
Walls
Ceilings/Floors
Unvented Attic Roof (Hot/Humid Climates)
Vented Attic (Cold/Dry Climates)
Bonus Rooms over Garages or Cantilevered Floors
Crawlspaces
Hard to Insulate Areas
 
 
 
Ryan Haydel
Icynene Comfort Specialist
 
 
ICYNENE LD-C-50™ Spray Formula
Applied as a liquid, Icynene® expands to 100 times its volume in seconds to fill every crack and crevice while remaining flexible so that the integrity of the building envelope seal remains intact over time. Icynene's spray formula has an R-value of 3.7 per inch. It acts as a complete insulation and air barrier to minimize air leakage and seal the building envelope for optimal airtightness.

 
 
ICYNENE LD-CP-50™ Pour Fill Formula
Icynene®'s pour fill variation is an insulation and air barrier that injects the latest building technology into an older building to maximize energy efficiency while still preserving its original architectural details. Icynene® fills the wall cavity completely, starting at the bottom and slowly expanding upwards to 60 times its initial volume. Since Icynene expands in the direction of least resistance, it will not expand outward and damage the wall. The pour fill formula has an R-value of 4 per inch.
 


Walls

Problem(s):

  • Up to 40% of energy loss is due to uncontrolled air leakage
  • Up to 99% of moisture travels in the air and can build up inside a home through daily activities like cooking and showering. If moisture carried by air is allowed to move through the walls it can condense within the walls leading to related problems such as mold
  • Unwanted noises originating from plumbing runs or from the adjoining media room
  • Drafts causing hot/cold spots

Solution:

Icynene® is classified as an air barrier material. Sprayed in the walls, Icynene® creates a blanket of soft foam for superior air tightness. Icynene®'s open-celled structure remains flexible to expand/contract with the walls for consistent air-sealing over the life of the building.

Benefits:

  • Increased energy efficiency
  • Improved Indoor Air Quality (IAQ)
  • Peace and quiet
Icynene®-insulated wall

Ceilings / Floors

Problem(s):

  • Cold and uncomfortable floors
  • Unwanted noises on the main floor originating from the kids' recreational room in the basement
  • Buckling hardwood floors due to moisture build-up in the floor system

Solution:

Icynene® is easily applied overhead to insulate ceilings or floor joists to minimize airflow and reduce the transfer of unwanted sounds

Benefits:

  • Even floor temperatures for added comfort
  • Quieter spaces
  • Minimized potential of buckling hardwood floors
CATHREDRAL CEILINGS
Icynene® in cathedral ceiling application
Unvented Attic Roof (Hot/ Humid Climates)
Problem(s):
  • Energy loss associated with duct leakage
  • Moisture ingress in the attic
  • HVAC inefficiency

Solution:

As an air impermeable insulation Icynene® is approved for use in an unvented attic design. Applied to the underside of the roof deck, Icynene® converts the attic into an indirectly conditioned space.

Benefits:

  • Duct leakage remains within the conditioned space, eliminating the loss of conditioned air.
  • HVAC equipment stays cooler and works more efficiently for superior cooling performance, locking in energy savings.
  • Source of a roof leak is easily detectable for repair and the material is unaffected by the wetting/drying process, maintaining original performance once dried.
  • Sealing soffit vents controls rainwater or wind-driven moisture ingress for added durability.

 Unvented attic illustration

Vented Attic (Cold/ Dry Climates)

Problem(s):

  • Stack effect occurs when heated air escapes through the ceiling into the attic from upper levels of the home and is replaced in lower levels of the home by drawn-in, outdoor air. Conventional insulation, such as fiberglass and cellulose, doesn't meet air barrier standards (based on air permeability testing, ASTM E 283) so doesn't do a good job of stopping air flow/leaks and can sag or settle over time.
  • In heavy snowfall areas, ice damming is a common problem.

Solution:

When spray applied to the attic floor and connected with the vertical wall insulation, Icynene® creates an air barrier against air leaks to minimize heat loss into the attic, particularly around hard to insulate areas like recessed lights.

In colder temperatures, Icynene® (as an ASTM qualified air barrier) addresses the problem of stack effect by minimizing heat loss through the ceiling. Icynene® minimizes the potential of warm moist interior air coming into contact with the cold roof surface; helping reduce the potential of ice damming in high snowfall areas.

Benefits:

  • Improves energy performance for savings as much as 50%.
  • Minimizes the potential of water/moisture damage and associated health concerns (mold) that can result from ice dams.

VENTED ATTIC
Vented attic illustration

Bonus Rooms / Cantilevered Floors

Problem(s):

  • The bonus room over the garage or porch is often uncomfortable. In cold climates, for example, floors can be 10°F cooler than the room.
  • Difficult to keep conventional fibrous insulation in contact with the floor above (when insulating the garage ceiling). Due to voids/air spaces in fibrous insulation, the floor in the bonus room is colder than the rest of the home.
  • Without extra sealing material, conventional insulation can allow exterior air, exhaust fumes and odors to penetrate from the garage or exterior into the living space above.

Solution:

Icynene® spray formula has tenacious adhesive characteristics making it easier to insulate overhead ceilings. It creates a seamless bond with the substrate providing consistent R-value without sagging.

Benefits:

  • Creates healthier indoor air by protecting the adjoining living space against fumes originating from the garage below.
  • Creates an evenly heated/cooled interior space for optimal comfort.
INSULATED GARAGE UNDER BONUS ROOM
Icynene®-insulated garage under the bonus room

Crawl Spaces

Problem(s):

  • Potential moisture build-up on floor insulation if conventional material is used.
  • Sweating ductwork.
  • Energy loss due to leaky ductwork/HVAC inefficiency.

Solution:

Icynene® air-seals and creates unvented crawlspaces, delivering a conditioned area that works more efficiently and improves indoor air quality.

Benefits:

  • Offers a conditioned area for ductwork and air handlers, allowing the HVAC equipment to operate more efficiently for increased energy savings.
  • Air-eals difficult-to-insulate areas with no gaps or seams.
  • Increases durability of the structure.
  • Circulates cleaner air inside the home.
  • Minimizes airflow and accompanying moisture from entering the crawlspace and condensing on the ductwork.
INSTALLED AROUND DUCT WORK
Icynene® installed around ductwork in attic

Hard to insulate areas

Problem(s):

  • Designs or architectural features can pose insulation challenges because conventional insulation doesn't fit unusual cavities.
  • Batts are standard size and must be cut or manipulated or compressed to fill unusual spaces (electrical boxes) reducing its rated R-value; and may require extra finishing materials.
  • Steel framing consists of ''U'' and ''C'' sections, double studs and non-standard stud locations that make insulating a challenge.

Solution:

Icynene® spray foam expands and fills all gaps, allowing you to explore the geometry of design without sacrificing function. It adheres to surrounding materials, creating a perfect air-seal and delivering the rated R-value in one step.

Benefits:

  • Conforms to unusual geometry to provide a seamless air barrier.
  • Increases the durability of the structure by providing consistent R-value for the life of the building.
  • Minimizes the flow of airborne moisture and the threat of condensation particularly in metal buildings.
  • Flexible allowing it to expand and contract along with the building structure preventing delaminating and cracking.
ELCTRICAL & PLUMBING
Icynene® installed around electrical and plumbing work
 
 

ICYNENE 3

 
 


   

 

© Copyright 2012, Butcher Air Conditioning. All rights reserved.

101 Boyce Road | Broussard LA 70518 | 337.837.2000 office | Email